Product Detail
- AC Inlet
- Outlet Pipe Connector
- Cooling Condensated water intake
Advantages:
- Applicable to air conditioners below 36.000 B.T.U
- Vertical water head up to 6 meters
- CE Certified
- Embedded outlet design to avoid breaking when installed or water streamed onto the body caused failue
- The check valve design to prevent colling condensed water setback from the discharge pipe no limit to even high or low water discharge
- Insulated housing design gor no dew and water coherence on the case surface
Advantages:
- Small Hippo is applicable to any brand of split type air conditioners below 25.000 B.T.U
- Independent Power switch design easy installation and maintenance capacity
- The max vertical water head is 3M, device running quiet with high drainage capacity
- Check valve design prevents cooling condensed water setback from inside of drainage pipe, no limit to even high or low water discharging
- Insulated housing design no dew or water coherence on case surface
- No hole drilling or wall breaking, easy and simple installation is more in corrdination with interior decorating.
- Easy installation steps, just 5 minutes to use
- Theme power conversion plug, in addition to easy installation and maintenance, the special design on the power cord “waterproof into the power hole with a cover block” to avoid failure and increase safety
Installing
- Power installation type two: Connect both condensate pump and air conditioner’s power cord and plug in power supply to power source
- Power installation type three: Connect condensate pump power cord into air conditioner control board’s power wires (Make sure it’s not control lines)
Warning:
Please check the power source is connecting with uninterruptible power source
- A. Suggest placing condensate pump on left or right below air conditioner with 15 cm space in between, and use tool to drill two holes on the wall
- B. Use the srews from the package and crew the hanger board with the plastic screw heads to a fixed condition
- C. Place condensate pump’s back support hole to hanger board and keep condensate pump in an even horizontal level. Attention: Hanger board must be place correctly to condensate pump’s back support hole
- D. To avoid clog or malfunction, do not tie too tight on the belt or strip when fixed tubes on the wall. In order to have siphon reaction outlet discharging tube must be lower than condensate pump 30 cm
- E. Connect the condensate power cord and pour water into water inlet for testing. After making sure the pump is running functionally, place air conditioner’s outlet pipe to condensate pump’s water inlet hole to finish installation